Model | V100 |
Color | White |
Voltage | AC 110 / 220 V |
Frequency | 50Hz/60Hz |
Power | 100 W Max |
Current | 2A Max |
Striking Strength | 5 – 250 MJ |
Working Frequency | 1 – 16 Hz |
Number of Working Heads | 14 |
Net Weight | 1.89Kg |
Gross Weight | 3.287Kg |
Instrument Dimensions | 197 X 145 X 63 MM |
Package Size | 413 X 331 X 113 MM |
Certification | CE Certification、CFF Certification |
Product Advantages

Lightweight and portable design
Equipped with a special portable packaging bag containing shock-absorbing materials, it can effectively absorb external impact and prevent damage to the instrument. The overall size is small and the weight is only 3.3 kg. Whether at home, in the office or on the road, users can easily carry it and enjoy convenient physical therapy services anytime, anywhere.

TFT Smart Touch Screen
The TFT smart touch screen is an advanced interactive interface technology in shock wave therapy devices. It combines display functions with touch operations to provide a unique and convenient user experience. The TFT screen provides clear and vivid visual feedback, allowing users to easily view and adjust various parameters.

Diverse Mode Physiotherapy
Equipped with up to 12 rich therapy modes, it can be used in combination with different types of treatment heads. It covers personalized solutions for different diseases and body parts, and is suitable for a wide range of people.

Precise Adjustment
Users can precisely adjust parameters such as frequency, energy and number of times according to specific treatment needs. The adjustable frequency function can customize the shock wave frequency to suit different tissue types and treatment stages. By fine-tuning the energy, the device can output shock waves of appropriate intensity to ensure treatment effectiveness while minimizing discomfort. The adjustable number of parameters allows users to precisely control the number of shock wave pulses to ensure stability and reliability of each treatment.
Product Display

Product Details

Instrument Heat Dissipation Design
The shock wave therapy device uses a grid design for heat dissipation. On the surface of the device, there are long lattice openings. This design can increase the contact area between the device and the air. Using the principle of air convection, cold air from the outside flows into the device, taking away the heat generated by operation. The hot air is then exhausted through the vents, maintaining a stable temperature inside the product. In addition, the four corners of the product can be equipped with foot pads to help lift the product, further optimizing the air circulation at the bottom and improving the heat dissipation effect.

Handle Front Part
The front end of the handle can be replaced with a variety of working heads to suit the treatment requirements.

Working Handle Heat Dissipation Design
The multi-hole design with efficient heat dissipation is designed to prevent the handle from overheating during the treatment.

Handle Power Button
The ON/OFF button controls the shock wave therapy, located on the handle, press the power button to start the machine, press the button again to turn off the therapy, easy to operate.

Main Unit
The mainframe is compact and lightweight, which is easy to carry for outside use. The machine body is made of durable material, which is resistant to collision and friction.

Out Handle Socket
Out Handle Socket is a multi-pin metal interface marked with “OUTPUT”, which means “output”. This interface design can ensure the stability and reliability of the electrical connection, and can stably transmit the energy generated by the main unit of the physical therapy device to the working handle, and then accurately act on the treatment part of the human body, providing stable energy output support for shock wave therapy.

Power Cord Socket
The power cord socket is a common three-hole herringbone interface. This interface can provide a stable power connection. One hole is used for grounding to ensure the electrical safety of the equipment during use and to prevent the risk of electric shock due to leakage. The other two holes are connected to the live and neutral wires, respectively, to carry the power required by the physiotherapy equipment to ensure normal operation of the equipment.
Transmitter Heads Introduction

1#Acupuncture head
8mm
Subtle deep acupoint stimulation

2#small divergent work head
15mm
conditioning of acupoints of human limb joints

3#focused work head
15mm(concave)
deep conditioning of large muscle groups

4#Focused Work Head
20mm(concave)
Deep stimulation and conditioning of small muscle groups of the human body

5#Divergent Work Head
36mm
By default, it is installed on the handle to condition the surface muscles of large muscle groups (such as waist and buttocks) of the human body

6#
Flat Head
Used for regulating male functional plates
(such as: male prostate, sexual dysfunction)

7#
Cylinder-shaped Head
For regulating the deep parts of male functional plates

Silicone Head
For treatment of highly sensitive regions

Silicone Head
For treatment of highly sensitive regions
Warm Tips
①Keep the massage close to the skin.
②Turn off the power switch of the device when changing the working head or unplugging the plugs.
③If the impact force is too strong, use the silicone massage head to reduce the impact force.
Pages of Using Instrument

Power-on Interface
First connect the working handle to the host, then connect the power cord to the host, and finally turn on the power. The instrument enters the power-on interface. The default password is 23456.

Welcome Screen
The welcome screen has three buttons: Settings, Shutdown, I have learned.You can select the language in the settings

Mode Selection
The shock wave therapy device offers 12 customized treatment modes that can be flexibly selected according to different disease types, patient tolerance and treatment stage.

Adjust Parameter Interface
The device comes with preset values for different modes. Taking the “Currency” mode as an example, you can see the settings of number, energy level and frequency in the user interface. You can easily adjust the parameters. It is recommended to start with a lower frequency to gradually accustom the body to the stimulation. At the same time, the device has two recommended working heads for different modes, and you can also choose according to the actual conditions.
Remark: Please use from low to high power to ensure your safety and comfortable usage.
Instrument Parameter Setting
- Output frequency range detail parameter: 16 range, continuously adjustable (1Hz–2Hz–3Hz–4Hz–5Hz–6Hz–7Hz–8Hz–9Hz–10Hz–11Hz–12Hz–13Hz–14Hz–15Hz–16Hz)
- Output energy level gear detail parameter: 27 gear, continuously adjustable(5mJ–10mJ–15mJ–20mJ–30mJ–40mJ–50mJ–60mJ–70mJ–80mJ–90mJ–100mJ–110mJ–120mJ–130mJ–140mJ–150mJ–160mJ–170mJ–180mJ–190mJ–200mJ–210mJ–220mJ–230mJ–240mJ–250mJ)
- Strike number adjustment gear detail parameter: 5 gear, continuously adjustable(500times–1000times—1500times–2000times–2500times)
Technical Principles
This device adopts advanced electromagnetic wave technology, which uses high-voltage pulse current to generate a magnetic field through a coil, driving the projectile to move and generate shock waves. It can not only achieve focused plane shooting, but also scatter the force deep into the fascial layer to loosen the adhered muscles and fasciae, thereby significantly relieving pain, performing corresponding conditioning, and helping users to restore physical comfort and health.
Package List

1 x Host
1 x Handle with cable
1 x Power cord
7 x Transmitter heads
7 x Soft tip heads
5 x Silicon rubber cases
1 x Storage bag
Common Applicable Symptoms

Frozen Shoulder
A frozen shoulder involves stiffness and pain in the shoulder joint. Shockwave therapy disrupts the fibrous tissues to promote blood flow and also breaks up the calcified deposits in the shoulder and loosens the joint structures to encourage calcium resorption, decrease pain, and improve shoulder function.

Tenosynovitis
Tendinitis occurs mostly due to prolonged and excessive use of a particular joint, which causes repetitive friction between the tendon and the tendon sheath, resulting in damage and inflammation of the tendon sheath. Shockwave therapy works by generating high-energy shockwaves that penetrate the skin and act on the affected area of tendovaginitis. It helps to relieve pain and restore the normal structure and function of the tendon sheath, improving the mobility of the joint and allowing the patients to move the affected joint freely again.

Tennis Elbow
Tennis elbow is a painful condition triggered by repetitive wrist and arm movements when there is excessive tension in the tendons of the elbow. The pain is primarily located in the tendons of the forearm muscles attached to the outer bony mass of the elbow and can also spread to the forearm and wrist. Shockwave therapy uses shockwaves to break down the affected tissue, stimulate rapid healing, and trigger the regenerative repair process of bones, tendons, and other soft tissues, which is highly effective in treating epicondylitis.

Plantar Fasciitis
The causes of fasciitis are mainly related to factors such as strain and trauma. Prolonged heavy physical labor, or maintain poor posture, such as sedentary, standing for a long time, will make the myofascia continue to be in a state of tension, and over time it is easy to cause fasciitis. Shockwave therapy through energy shockwave effect on the inflammation of the fascia, can directly impact the lesion, so that patients can get rid of fasciitis brought about by the trouble.

ED(Erectile Dysfunction)
The instrument acts on ED (Erectile Dysfunction) by utilizing low energy shockwaves to stimulate the cavernous body of the penis. It can prompt the release of vascular endothelial growth factor, promote new blood vessels, and improve the blood supply to the cavernous body of the penis. At the same time, the shock wave can also repair damaged cavernous tissue, enhance erectile function and improve the quality of sexual life.
Reviews
There are no reviews yet.